Human IL-12p70 Kit (HICA)Product Specification Stability & Storage Store at 2~8C protected from light for 12 months; the reconstituted standard can be aliquoted and stored at 20C, avoiding repeated freeze thaw cycles. Background Principle of the Assay: This kit employs a homogeneous immuno chemiluminescence assay (HICA) based on the double antibody sandwich principle for the detection of cytokine concentrations. The operation is simple and requires no washing steps. The
Product Specification
| Stability & Storage | Store at 2~8°C protected from light for 12 months; the reconstituted standard can be aliquoted and stored at -20°C, avoiding repeated freeze-thaw cycles. |
Background
Principle of the Assay:
This kit employs a homogeneous immuno chemiluminescence assay (HICA) based on the double-antibody sandwich principle for the detection of cytokine concentrations. The operation is simple and requires no washing steps.
The detection system includes two types of microspheres: acceptor microspheres conjugated with antibody 1 targeting the protein of interest, and donor microspheres conjugated with streptavidin, along with biotin-labeled antibody 2. During the reaction, the target protein binds with the antibodies and microspheres to form an immune complex, bringing the two types of microspheres into close proximity. When the distance between the donor and acceptor microspheres is less than 200 nm, singlet oxygen generated upon light excitation can transfer to the acceptor microspheres, triggering chemiluminescence. Conversely, if the target protein is absent, the microspheres remain too far apart, resulting in no signal.
By measuring the intensity of the chemiluminescent signal, quantitative analysis of the target protein can be achieved. This method is characterized by its simplicity, rapid reaction, and high sensitivity.
Components
Name |
Specification |
Component Specification |
Detection ReagentR1A |
500T |
1mL/bottle×1 |
2000T |
4ml/bottle×1 |
|
10000T |
20ml/bottle×1 |
|
Detection ReagentR1F |
500T |
1mL/bottle×1 |
2000T |
4ml/bottle×1 |
|
10000T |
20ml/bottle×1 |
|
Detection ReagentR2 |
500T |
1mL/bottle×1 |
2000T |
4ml/bottle×1 |
|
10000T |
20ml/bottle×1 |
|
Detection ReagentR3 |
500T |
6mL/bottle×1 |
2000T |
24ml/bottle×1 |
|
10000T |
120ml/bottle×1 |
|
Standard |
500T |
0.045μglyophilized powder×1 |
2000T |
0.045μglyophilized powder×2 |
|
10000T |
0.045μglyophilized powder×5 |
|
StandardBuffer |
500T |
6ml/bottle×1 |
2000T |
12ml/bottle×1 |
|
10000T |
30ml/bottle×1 |
Note: Recommended plates are microplates (384or96-well plates, white, flat-bottom)
Guidelines
Reagent R3 should be protected from light. It is recommended to perform sample addition and incubation under green light (<100 LUX).
Recalibration is required for each test. At least two replicates of each standard concentration should be tested, and a four-parameter (weighted 1/Y²) fitting calculation should be applied.
Temperature and time should be strictly controlled during incubation. The microplate should be covered with a film, and a microplate reader with ALPHA function is recommended.
The dilution matrix of the calibrator should be consistent with the test samples. The reconstituted solution should be used within 2 hours.
Components from different reagent kit batches must not be mixed.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy